Early leak detection on a water distribution network

A treatment plant and the network it supplies, where a burst pipe was only discovered when someone complained about having no water.

The demo runs on its own: the cursor opens a unit, reads the sensors and corrects. You can also click any unit, sensor or valve.

COA Água Kikolo plant · Cazenga network · Afternoon shift · 14:00–22:00 Online --:-- Operations · L. Kiala
Water treated today—
Network flow—
Treated-water reservoir—
Residual chlorine—
Active alerts—
River intake TU-101— ! P-01Intake pump! V-01 T-01 Coagulation and flocculation AI-102— ! T-02 Clarifier TU-102— ! F-01 ! F-02 ! DP-201— DP-202— D-01 AIT-301— ! — % R-01 Treated-water reservoir LT-401— ! P-02Booster station! V-03 V-04 V-05 V-06 PT-201— FT-201— PT-202— Distribution network ! — % R-02 ! North sector South sector Air quality · neighbourhood PM2.5— PM10— NO2— ! Weather station TT-501— RH-501— WS-501— ! Network · last few minutes PT-202 · bar FT-201 · m³/h
Shift log

    A representative scenario, built from the problems we see most often in this kind of site. Exact figures vary from one installation to another.

    Starting point

    The network supplies two sectors from a treated-water reservoir, with pressure measured only at the plant outlet, once a day, by the shift operator.

    Main problem

    A burst somewhere in the network dropped pressure without anyone at the plant knowing, and the first sign was a resident's call hours after the leak had started.

    Solution put in place

    Pressure and flow sensors at critical points of the network feed COA Água. A pressure drop with rising flow triggers a probable-burst alert, and the operator can isolate the affected sector from the screen while the team is on the way.

    Key results

    After instrumenting the network:

    -60%

    time between the burst and its detection

    -25%

    non-revenue water

    +30%

    filter service life, with backwashing at the right moment

    Day to day

    What the team sees on screen

    COA-IoT
    COA Água — Sinóptico da rede Últimas 3 horas
    Pressão média
    4.1 bar
    -0.6 bar
    Caudal total
    134 m³/h
    +34%
    Setores normais
    1/2
    -1
    Pressão por setor (bar)
    Setor Norte Setor Sul
    Setores
    Setor Norte Pressão a cair, caudal a subir Rotura provável
    Setor Sul Dentro do normal Normal
    Reservatório principal 78% de capacidade Normal

    COA Água — Sinóptico da redeMimic of the plant and the network, with both sectors' pressure live.

    COA-IoT
    Setor Norte — Ficha Última hora
    Pressão
    2.8 bar
    -1.3 bar
    Caudal
    134 m³/h
    +34%
    Pressão (bar)
    45% Pressão vs. normal
    normal Turvação

    Setor Norte — FichaThe network's critical point: pressure, flow and the last few minutes of history.

    Does this sound familiar?

    Tell us about your site. We survey it in person and tell you, before proposing anything, what is worth measuring and at what cost.